{"id":283,"date":"2020-02-25T09:55:23","date_gmt":"2020-02-25T09:55:23","guid":{"rendered":"http:\/\/new.pie.ch\/?page_id=283"},"modified":"2025-06-27T05:54:11","modified_gmt":"2025-06-27T05:54:11","slug":"versatile-trigger-unit","status":"publish","type":"page","link":"https:\/\/pie.ch\/en\/versatile-trigger-unit\/","title":{"rendered":"Versatile Trigger Unit"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Trigger unit for analog signals<\/h2>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"347\" src=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/01\/Versatile_Trigger_Unit.jpg\" alt=\"\" class=\"wp-image-54 size-full\" srcset=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/01\/Versatile_Trigger_Unit.jpg 600w, https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/01\/Versatile_Trigger_Unit-300x174.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>The&nbsp;<strong>Versatile Trigger Unit<\/strong>&nbsp;converts the output signals of sensors into a digital 5V and 12V signal. The integrated, automatic scaling speeds up the operation of the device and the integrated, digital signal processing makes even the processing of complex signals possible. <\/p>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Typical application<\/h3>\n\n\n\n<p>The diagram below shows the Versatile Trigger Unit in operation on a rotating machine. The analog signal of an inductive sensor is digitized and processed so that it can be used as a clean trigger signal for a subsequent data acquisition.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"488\" src=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/Versatile_Trigger_Unit-Scope_Plot.jpg\" alt=\"\" class=\"wp-image-286\" style=\"width:450px;height:366px\" srcset=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/Versatile_Trigger_Unit-Scope_Plot.jpg 600w, https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/Versatile_Trigger_Unit-Scope_Plot-300x244.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\n\n\n<p>We will gladly demonstrate the device here in Baden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Unique properties<\/h3>\n\n\n\n<p>The&nbsp;<strong>Versatile Trigger Unit<\/strong>&nbsp;combines the advantages of analog and digital trigger technology.<br>Analog triggers have a high temporal resolution and are fast. However, signal processing and interference suppression can only be implemented to a very limited extent.<br>Digital triggers, on the other hand, offer extensive possibilities for signal processing and interference suppression. However, the temporal resolution is limited.<br>A unique design creates a trigger device that combines the time resolution of an analog trigger and the comprehensive signal processing of a digital trigger. This makes it possible to perform various measurement tasks with better quality. <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"772\" height=\"1024\" src=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/NanoJitterOption-772x1024.png\" alt=\"\" class=\"wp-image-287\" style=\"width:579px;height:768px\" srcset=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/NanoJitterOption-772x1024.png 772w, https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/NanoJitterOption-226x300.png 226w, https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/NanoJitterOption-768x1019.png 768w\" sizes=\"(max-width: 772px) 100vw, 772px\" \/><\/figure><\/div>\n\n\n<div style=\"height:63px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-2-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Downloads<\/h3>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/08\/Project_sheets_A4_PI608-Pulsformer_Pulsformer.pdf\">Flyer Versatile Trigger Unit<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/08\/Project_sheets_A4_PI608-Pulsformer_NanoJitter.pdf\">Flyer Nano Jitter Option<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/PI608-Versatile_Trigger_Unit_Data_Sheet_V1.1.pdf\">Datasheet<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/TN608-01_Quick_Start_Settings.pdf\">Quick Start Settings<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/Account_Solution_Slide_-_PI608_Versatile_Trigger_Unit.pdf\">Customer use<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">White Papers<\/h3>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/TN608-02_HOLDOFF.pdf\">Blocking parasitic triggering with the Holdoff function<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/TN608-03_Filters_and_Holdoff.pdf\">The Use of Filters and Holdoff<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size is-style-primary has-small-font-size\"><a class=\"wp-block-button__link has-neve-link-color-background-color has-background wp-element-button\" href=\"https:\/\/pie.ch\/wordpress\/wp-content\/uploads\/2020\/02\/TN608-04_Time_Domain.pdf\">Better Understanding of Filters in the Time Domain<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Triggereinheit f\u00fcr analoge Signale Die&nbsp;Versatile Trigger Unit&nbsp;wandelt die Aus\u00adgangs\u00adsignale von Sensoren in ein digitales 5V und 12V Signal. Die integrierte, automatische Skalierung beschleunigt die Bedienung des Ger\u00e4ts und die inte\u00adgrierten, digitalen Signal\u00adverarbeitungen machen selbst das Auf\u00adbe\u00adreiten von komplexen Signalen m\u00f6glich. Typischer Einsatz In der untenstehenden Grafik sieht man die Versatile Trigger Unit an einer rotierenden&hellip;&nbsp;<a href=\"https:\/\/pie.ch\/en\/versatile-trigger-unit\/\" class=\"\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">Versatile Trigger Unit<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"neve_meta_sidebar":"full-width","neve_meta_container":"","neve_meta_enable_content_width":"on","neve_meta_content_width":100,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"_links":{"self":[{"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/pages\/283"}],"collection":[{"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/comments?post=283"}],"version-history":[{"count":34,"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/pages\/283\/revisions"}],"predecessor-version":[{"id":1776,"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/pages\/283\/revisions\/1776"}],"wp:attachment":[{"href":"https:\/\/pie.ch\/en\/wp-json\/wp\/v2\/media?parent=283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}